TM 1019 Condition D, explained

Condition D is the low-dose-rate test condition in MIL-STD-883 Test Method 1019, used to screen for Enhanced Low Dose Rate Sensitivity (ELDRS). This overview covers what it is, how long it takes, and what to plan for.

Updated October 2026 · An overview for planning, not a substitute for the standard

In one sentenceTM 1019 Condition D irradiates devices with Co-60 gamma rays at a low, standardized dose rate of 10 mrad(Si)/s (or a lower or otherwise agreed rate) so that ELDRS-susceptible parts show the degradation a fast test would miss.

What Test Method 1019 covers

MIL-STD-883 Test Method 1019 defines how to test microcircuits for total ionizing dose (TID) effects using a Co-60 gamma source. It sets out several test conditions. Condition A is the familiar high-dose-rate test, run at 50 to 300 rad(Si)/s, where a typical qualification dose is reached in minutes. Condition D is the low-dose-rate condition used for parts that may be ELDRS-susceptible.

Why a separate low-dose-rate condition exists

Many bipolar and BiCMOS linear and mixed-signal devices degrade more at low dose rate than at high dose rate for the same total dose. A high-dose-rate result can therefore understate how a part will behave in orbit. Condition D exists so that this sensitivity is measured directly rather than assumed away.

Condition D's rate is a test convention. Actual dose rates in orbit are typically far lower, so the low-dose-rate test is a practical compromise between realism and schedule.

How long a Condition D test takes

Duration is simply total dose divided by dose rate. At 10 mrad(Si)/s, every 10 krad(Si) takes about 11.6 days:

Illustrative test targetDays at 10 mrad(Si)/sWeeks
10 krad(Si)11.61.7
20 krad(Si)23.13.3
30 krad(Si)34.75.0
50 krad(Si)57.98.3
100 krad(Si)115.716.5

Those figures are irradiation time only. Pre-irradiation characterization, interim readouts, any post-irradiation anneal and shipping all add to the calendar. Our duration calculator adds dose margin and anneal time and gives a completion date.

What a Condition D setup involves

  • A stable Co-60 source position that can deliver a constant, low dose rate at the device location for weeks to months.
  • A lead/aluminum (Pb/Al) filter box around the devices to reduce low-energy scattered radiation that would otherwise cause dose errors. ASTM E1249 addresses minimizing these dosimetry errors in Co-60 testing.
  • Bias during irradiation as specified in the test plan. Bias condition can strongly affect results, and some programs test both biased and unbiased samples.
  • Dosimetry to establish and verify the dose rate at the device positions, with calibration traceable to national standards.
  • Electrical measurements before irradiation, at interim dose levels and after irradiation, within the time limits the method sets.
  • Records of accumulated dose, interruptions, environmental conditions and chain of custody.

Anneal and rebound steps

Post-irradiation steps depend on device technology and the procedure you specify. Method 1019's extended rebound test, an additional dose followed by an elevated-temperature biased anneal, applies mainly to MOS devices. For bipolar ELDRS testing, follow the anneal requirements in your test plan and the current revision of the method.

Planning tips

  1. Reserve the window early. A Condition D exposure ties up a source position for its full length, so capacity is the usual constraint.
  2. Fix the test plan before booking: dose, rate, bias, sample size, readout points and anneal.
  3. Build bias boards for the full duration, including connectors and cabling that will run unattended for weeks.
  4. Plan interim readouts so a failing lot is caught before the full exposure ends.
  5. Add calendar margin for shipping, setup, dosimetry verification and post-irradiation work.

This page is a general overview for planning. Always work from the current revision of MIL-STD-883 Test Method 1019 and your program's requirements. Parapet Radiation Lab is a planned facility; testing is not yet offered.

2028 capacity

Tell us what you'll need in 2028

We are sizing first capacity around real programs. An inquiry doesn't commit you to anything. It starts an engineering conversation about your parts, doses and timing.

Prefer email?
lab@parapetradiationlab.com
Location

Washington, DC region

Privacy

We use what you send only to respond to your inquiry and plan capacity. We don't sell or share it. Ask us at any time to delete it.

2028 capacity inquiry
About two minutes. We reply within two business days.
To ask about 2028 capacity, email lab@parapetradiationlab.com with your organization, testing timeframe and approximate campaigns per year.